jaeaa.blogg.se

Brocade san switch command
Brocade san switch command






brocade san switch command

These errors are in the sum for the LLI errorsĬRC with good EOF (End Of Frame) recieved. Statistically, enc out errors alone imply cable problems, the enc out and crc err in combination implies GBIC/SFP problems. Frames that fail a CRC are noted but not modified and the destination device is responsible for rejecting and/or re-requesting the frame. For the purpose of CRC computation, the bit of the word-aligned four-byte field that corresponds to the first bit transmitted is the highest order bit. The CRC field shall be aligned on a word boundary. The CRC field shall be calculated on the Frame header and Data Field prior to encoding for transmission and after decoding upon reception. SOF (= Start-Of-Frame) and EOF (= End-Of-Frame) delimiters shall not be included in the CRC verification. The Cyclic Redundancy Check (CRC) is a four-byte field that shall immediately follow the Data Field and shall be used to verify the data integrity of the frame header and Data Field. These errors are in the sum for the LLI errors.įrames with Cyclic Redundancy Check errors: (RX) The number of frames that have failed a Cyclic Redundancy Check. Reinitialization and reboots of associated Nx-port can also cause these errors. Minimum compliance with the link-bit error rate specification on a link continuously receiving frames would allow approximately one error every 20 minutes for 1 Gb/s. This counter is generally a zero value, although occasional errors may occur on a normal link and give a nonzero result. The number of 8b/10b encoding errors that have occurred inside frame boundaries.

brocade san switch command

This number is a statistic that provides a baseline for the error counters.Įncoding errors inside frames: (RX). This number is a statistic that provides a baseline for the error counters.įrames received: The number of frames transmitted by the port. Причинаįrames transmitted: The number of frames transmitted by the port. One output line is displayed per port, and shows error counters in ones, thousands (the number is followed by k), or millions (the number is followed by m). This command displays an error summary for all ports.

#Brocade san switch command how to

Interprets and explains the porterrshow output (port errors) of Brocade SAN switches and possible causes of the errors.įor action to be taken when counters increase see the copy of the KB articleĬonnectrix: How to troubleshoot Fibre Channel node to switch port or SFP communication problems by means of elimination?įrames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor How to Interpret the Brocade porterrshow output








Brocade san switch command